ULTRASONIC PULSE VELOCITY METER

Propagation velocity of a mechanical pulse in a material depends on several parameters including material density and its elastic properties. These parameters in turn, are related to the material’s mechanical properties such as quality, homogeneity and strength. The Ultrasonic Pulse Velocity Meter Model FU202 is a cost effective, reliable and accurate instrument for measuring the speed of sound in a given sample of rock, concrete, ceramic, wood, plastic etc. and covers all the requirements of ASTM C597 standard.k

Test method

In ultrasonic pulse velocity testing two transducers are connected to the ends of a sample using a couplant. The transmitting device generates a mechanical pulse wave. This wave propagates through the sample and is received by the other transducer. The instrument measures this propagation time , also known as time of flight. Knowing the length of the sample and the time of flight, sound speed in the material will be calculated and displayed. The best testing frequency depends onmaterial type and its grain size. For concrete, 54 kHz P-Wave transducers and 180…۲۵۰kHz S-wave transducers have proved to be the most efficient. The transducer body is designed to tolerate mechanical pressure for testing samples under axial force. k

Features

 Ruggedized Aluminum Case Which is Compatible to Both Laboratory and Field Applicationsl

Light Weight Handheld Device with Intuitive Menu Operation

 Timing and Signal Level Measurement Performed by Shortcut Keys

  Pulse Repetition Rate, Timing, Count and Intensity Adjustable by Userl

Hold Key for Freezing the Waveform Displayl

Operating Modes: Pulse Velocity /Transmission Time / Distance, Line Scans, Compressive Strength

 Waveform Display and Storage for Future Referencel

Easy Length/ Velocity / Time Period Input

Applications

l l Evaluation ofHomogeneity of a Materiall

Detection of Voids, Cracks or other Defects

l Evaluation of Concrete Aging and Changes Over Time

l Evaluation of concrete damage caused byoverheating, freezing or chemical exposurel

Evaluation of concrete damage caused byoverheating, freezing or chemical exposurel Evaluating of the strength or poisons modulus of materialsl

Qualifying the concrete according the specified standard requirements

Specifications